T-Class air-cooled chillers
T-Class is the optimal solution for applications requiring quiet, efficient cooling.
So quiet you can have a normal conversation standing next to the machine at full load!
30-520 TR (105-1830 kW)
Oil-free compressor(s): R1234ze, R515B, R513A, and R134a
AHRI Certified, ETL Certified, CE
Revolutionary low-noise operation with high efficiency
When noisy cooling systems are a big concern, Smardt provides the optimal solution: T-Class oil-free chillers.
A chiller that knows when to hush
Smardt T-Class sound ratings are typically below 85 dBA at 1 meter. That’s about 20 dBA lower than oil-lubricated air-cooled screw chillers—almost 25% quieter.
The Smardt T-Class is ideally suited for installations where excessive noise is not permitted at certain times, such as residential neighborhoods at night. The system’s Active Noise Control feature allows you to limit the chiller’s sound output during specific periods of operation.
40% more efficient than ASHRAE code
Variable speed enables the Smardt T-Class chiller to precisely match capacity with greater energy efficiency. In comparison to ASHRAE® 90.1-2016, Smardt T-Class oil-free air-cooled chillers have Integrated Part Load Values (IPLV) that perform 40% more efficiently.
What’s more, Smardt’s Free-Cooling* integrates special bypass circuitry, controls, and safeguards. Our optional Free Cooling package can dramatically increase T-Class chiller efficiencies at low ambient temperatures.
T-Class is an optimal solution for applications requiring quiet, efficient cooling, for office towers, greenhouse facilities and data centers.
Key features and benefits:
- Class leading part-load efficiencies, achieving optimum IPLV in total capacity range.
- Typically smaller footprint than chillers of comparable capacity.
- Responsive chilled water control under all conditions.
- Adaptable by design - a base range with options to suit any air-cooled application.
- Built-in compressor redundancy.
- Remote access.
- Designed for ease of maintenance and serviceability.
- Optional CPECs for further plant optimization.
An abundance of cost saving measures
Older variable-speed screw chillers require a large footprint on the roof top. They are noisy and energy intensive.
Smardt T-Class oil-free air-cooled chillers, by comparison are extremely quiet. They are also highly efficient, especially at part load. The result: lower power consumption when running your Smardt chiller.
Most Smardt customers realize immediate saving, with some Smardt installations actually paying for themselves within two years.
Your investment in any Smardt oil-free magnetic bearing chiller provides:
- Lower power consumption by 20 to 50%.
- Zero performance degradation.
- Smaller footprint: takes less real estate on your roof or plant room.
- Ease of installation: reduce cost on material and labor.
- Reduction in annual maintenance.